Theta series transducers come in a compact programmable design, they are available with LCD display, and on-site configurability. Dedicated versions measuring: Current, Voltage, Frequency or Power are also available.
Theta 10A/10V – AC Current or AC Voltage Transducer
Theta 10A/10V transducer converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
Features
- Accuracy class 0.2 as per International Standard IEC/EN 60688
- Output Response Time < 250 ms
Theta 20A/20V – LCD AC Current or AC Voltage Transducer
The Theta 20A/20V compact programmable Transducers are available with LCD display and are completely on-site configurable.
Features
- True RMS measurement
- On-site programmable inputs
Theta 30P – LCD Power/Phase Angle/Power Factor Transducer
The Theta 30P compact programmable Transducers are available with LCD display and are completely on-site configurable.
Features
- True RMS measurement
- On-site programmable inputs
Theta 40 – Programmable Multi Transducer
This series of multi-transducers simultaneously measure several variables of an electric power system and process them to produce 2 or 3 or 4 analogue output signals.
Features
- For all heavy-current power system variables
- Upto 6 outputs (2A + 4D or 4A + 2D or 2A or 3A)
Theta 50 – Isolator with Analogue outputs
Theta 50 is used to electrically isolate input, outputs & power supply.
Features
- Accuracy class 0.2 as per International Standard IEC/EN 60 688
- Output Response Time < 250 ms
Theta 60M – Universal Temperature Transducer
Transmitter Theta 60M available in housing S17 clipped onto a top-hat rail and in housing S17 screw hole mounting brackets pulled out.
Features
- Electric insulation between measured variable, analogue output signal and power supply / Safe isolation acc. to EN 61 010
Theta 60R – Pt 100 Temperature Transducer
Transmitter Theta 60R available in 1 channel version, in housing S17 clipped on to a top – hat rail and 2 channel version, in housing S17 hole mounting brackets pulled out.
Features
- Measuring ranges configurable with DIP switch and potentiometer
- Red LED’s indicator: an open or short-circuit
Theta Hz – LCD Frequency Transducer
Theta Hz the transducer is used for frequency measurement.
Features
- Fully onsite programmable input range
- Available in Single or Dual output type
Theta M – Three Phase (3or4 wire) AC Power Transducer
The Theta M transducer is used to measure and convert parameter of Three-phase 3W/4W AC power network with balanced or unbalanced system.
Features
- True RMS measurement
- Fully onsite programmable input PT & CT ratio
Theta PI102 – Programmable Dual output DC Isolator
The purpose of the THETA PI-102 is to electrically isolate input, outputs and power supply.
Features
- All input signal range and output signal range are user programmable.
- Electric isolation between input, outputs and power supply.
Theta 60I – Isolating Amplifier
The purpose of the isolating amplifier Theta 60I is to electrically insolate input and output signals
Features
- 252 standard input and output combinations selected by soldered jumpers
- User-specific input and / or output ranges
P17 – Temperature Transducer 4/20mA
The P17 transducer is destined to convert the signal from temperature, resistance or voltage sensors into a 4…20 mA current signal.
Features
- Can be treated as an active load forcing a current proportional to input signal changes from the supplying circuit
P17G – Separator (supplied from Current Loop)
P17G:– separator supplied from a current loop.
Features
- For the separation of measuring signals (eg in PLC).
- Thin casing – 6.2 mm.
P18D/P18L – Temperature Humidity Sensor
P18 Transducer of temperature and standard signals.
Features
- Built-in temperature and humidity sensor
- Calculation of selected physical quantities (dew-point temperature, absolute humidity)
P19 – Temperature and Humidity Transducer
P19 Temperature and Humidity Transducer.
Features
- Built-in temperature and humidity sensor
- Calculation of selected physical quantities (dew-point temperature, absolute humidity).
P20 – Programmable Temperature Signal Transducer
The P20 programmable transducer is destined to convert the temperature, resistance, voltage from shunt and standard signals into a standard constant-current or constant-voltage signal.
Features
- Input: programmable universal input
- Output: 0/4…20mA, 0…10V.
P20H – Programmable DC Transducer
Transducers of P20H types are applied for the continuous conversion of d.c. voltage and d.c. current into a standard d.c. current, d.c. voltage signal or RS-485 digital signal.
Features
- Preservation of the output signal at overflows
- Transmission parameters through RS-485.
P20Z – AC Current or AC Voltage Transducer
Measuring transducer P20Z type is destined to a continuous conversion of the rms current value or alternating voltage without the constant component into a standard d.c. current or d.c. voltage signal.
Features
- Input: 0…60 / 100 / 150/ 250/ 400 / 500 / 600 V a.c., 0…1 / 5 A a.c.,
- Output: 0/4…20mA, 0…10V.
P21Z – Programmable AC Current or AC Voltage Transducer
Measuring transducer P21Z type is destined to a continuous conversion of a.c. current or a.c. voltage without the constant component or frequency into a standard d.c. current or d.c. voltage signal or digital signal.
Features
- RS-485 with Modbus protocol
- Value of output signal when limit value are exceeded.
P30H – LCD Programmable DC Circuit Parameters with Ethernet
P30H is a transducer which was designed to photovoltaic , battery, telecommunication and railway installations. P30H measures and records current, voltage, power, energy and other d.c. circuit parameters.
Features
- Programmable input
- DC parameters.
P30O – LCD Pulse/Frequency/Turns/Operation Time Transducer with Ethernet
P30O Transducer of pulses, frequency, turns and operation time.
Features
- 2 universal pulse inputs
- Version: standard with SD card with ethernet and internal memory
P30O Frequency Transducer
Programmable transducer P30O type is destined to convert of number of pulses, number of working hours, frequency, period and rotational speed into a digital or standard current or voltage signal.
Features
- 2 universal pulse inputs.
- 3 versions.
P30P – LCD Transducer 1 Phase Power Network with Ethernet
Transducer of 1-phase power network parameters.
Features
- Measurement of 1-phase power network parameters.
- Conversion of measured value in an output signal on the base of the individual characteristics 1 or 2.
P30U – DC Temperature Transducer
P30U transducer is designed to convert temperature, resistance, standard voltage and current signals into a standard DC voltage or DC current signal.
Features
- Display: LCD 2 x 8 characters with backilit,
- Supply: 85..253 V a.c./d.c. or 20…40 V a.c./20…60 V d.c.
P43 – Programmable 3 Phase Power Transducer
Programmable Transducer of 3-Phase Power Network Parameters.