EMDC Multi Channel DC Energy Meter

Multi Channel DC Energy Meter - EM DC 6001 / 6002

EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target system

Features

  • Multi-Channel Support Single meter measures energy consumption of four independent loads connected to one Voltage source
  • Bi-Directional Voltage & Current measurement The meter has a unique feature of measuring both charging and discharging current
  • Event Logging Previous 5 Events of factory-default parameters can be logged with Date and Time stamp
  • Data Logging User Selectable parameters (1 to 30) can be logged at regular intervals (1 to 60 min) with Date & Time stamp in internal memory and can be accessed via MODBUS. Max Records can vary from 8533 to 91018 depending upon number of selected parameters.
  • Load Profile Analysis Logging of Energy consumed and Peak Demand (Power & Current) in a day and in a month for efficient tracking of load behaviour. Daily Data is available for last 1 year and Monthly Data is available for last 14 years.
  • Direct Remote Access (optional) Remote configuration of the Instrument and access of measured parameters via MODBUS. Programmable baud rates up to 57.6kbps.
  • Parameter Screen recall In case of power failure, the instrument memorizes the last displayed screen.
  • 4 - line 8 digit Ultra-bright LED Display 4 - line LED display provides easily readable data on meter front with a display range of 99999999.
  • Reverse Locking Energy and Ampere Hour accumulation can be blocked for Reverse Power and Current resp. Reverse condition can be set as Import or Export.
  • Onsite Configuration Configuration can be done via Front Keys, USB-based Serial Interface or RS485 (MODBUS). 
  • Relay Functions
  1. Limit Switch - For protection against over-shoot or under-shoot of any selected parameter
  2. Pulse Output - To drive an external counter for energy measurement
  3. Timer - Cyclic ON-OFF operation of relay for user-defined cycles with programmable ON-OFF   Delays
  4. Remote Operation - Relays can be activated remotely via Modbus
  5. Reverse Locking Alarm
  6. RTC Relay - Relay can be activated & deactivated at predefined ON & OFF Time on any or all Days of Week
  • Enclosure Protection for dust and water conforms to IP 54 (front face) as per IEC60529.
  • Compliance to International Safety standards Compliance to International Safety standard IEC 61010-1- 2010.
  • EMC Compatibility Compliance to International standard IEC 61326.

Digital download files available for Multi Channel DC Energy Meter - EM DC 6001 / 6002.