{"title":"Transducers \u0026 Isolators","description":"\u003cp\u003eTheta series transducers come in a compact programmable design, they are available with LCD display, and on-site configurability. Dedicated versions measuring: Current, Voltage, Frequency or Power are also available.\u003c\/p\u003e","products":[{"product_id":"theta-10a-10v","title":"Theta 10A\/10V – AC Current or AC Voltage Transducer","description":"\u003cp\u003e\u003cstrong\u003eTheta 10A\/10V\u003c\/strong\u003e\u003cspan\u003e transducer converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57560916033923,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta10V-1-332x332.jpg?v=1773233140"},{"product_id":"theta-20a-20v","title":"Theta 20A\/20V – LCD AC Current or AC","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eTheta 20A\/20V\u003c\/strong\u003e\u003cspan\u003e compact programmable Transducers are available with LCD display and are completely on-site configurable.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57560927568259,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta-20a-20V-692x692.gif?v=1784213765"},{"product_id":"theta-30p","title":"Theta 30P – LCD Power\/Phase Angle\/Power Factor Transducer","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eTheta 30P\u003c\/strong\u003e\u003cspan\u003e compact programmable Transducers are available with LCD display and are completely on-site configurable.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57560939430275,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta30P-1-332x332.jpg?v=1773233373"},{"product_id":"theta-40","title":"Theta 40 – Programmable Multi Transducer","description":"\u003cp\u003e\u003cspan\u003eThis series of multi-transducers simultaneously measure several variables of an electric power system and process them to produce 2 or 3 or 4 analogue output signals. 2 or 4 digital outputs are available for signalling limits or power metering. For two of the limit outputs up to 3 measurands can be logically combined.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoftware is available for this device\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease see the downloads tab for the software configuration \u0026amp; driver.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57560985469315,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta40-2-332x332.jpg?v=1773233497"},{"product_id":"theta-50","title":"Theta 50 – Isolator with Analogue outputs","description":"\u003cp\u003e\u003cb\u003eTheta 50 \u003c\/b\u003e\u003cspan\u003eis used to electrically isolate input, outputs \u0026amp; power supply. It fills all requirements \u0026amp; regulations concerning electromagnetic compatibility (EMC) \u0026amp; safety (IEC 61326-1 \u0026amp; IEC 61010-1-2010)\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561010372995,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta50-1-332x332.jpg?v=1773233853"},{"product_id":"theta-60m","title":"Theta 60M – Universal Temperature Transducer","description":"\u003cp\u003e\u003cspan\u003eTransmitter \u003c\/span\u003e\u003cstrong\u003eTheta 60M\u003c\/strong\u003e\u003cspan\u003e available in housing S17 clipped onto a top-hat rail and in housing S17 screw hole mounting brackets pulled out.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561034490243,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta60M-1-332x332.jpg?v=1773233969"},{"product_id":"theta-60r","title":"Theta 60R – Pt 100 Temperature Transducer","description":"\u003cp\u003e\u003cspan\u003eTransmitter \u003c\/span\u003e\u003cstrong\u003eTheta 60R\u003c\/strong\u003e\u003cspan\u003e available in 1 channel version, in housing S17 clipped on to a top – hat rail and 2 channel version, in housing S17 hole mounting brackets pulled out. The transmitter Theta R converts the input variable-a signal from a resistance thermometer Pt 100- to a temperature linear output signal.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561055068547,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta60R-1-332x332.jpg?v=1773234064"},{"product_id":"theta-hz","title":"Theta Hz – LCD Frequency Transducer","description":"\u003cp\u003e\u003cstrong\u003eTheta Hz\u003c\/strong\u003e\u003cspan\u003e the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561072533891,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta_Hz-with-wthout-display-692x692.gif?v=1784213833"},{"product_id":"theta-m","title":"Theta M – Three Phase (3or4 wire) AC Power Transducer","description":"\u003cp\u003e\u003cstrong\u003eThe Theta M\u003c\/strong\u003e transducer is used to measure and convert parameter of Three-phase 3W\/4W AC power network with balanced or unbalanced system.\u003c\/p\u003e\n\u003cp\u003eIt ensures that the measurement and conversion of measured values into standard analog current signals.Relay outputs signal the overflow of the selected quantities, and the pulse output can be used for the consumption monitoring of the 3- phase active energy.\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561107300739,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta_M-1-332x332.jpg?v=1773234333"},{"product_id":"theta-m-1","title":"Theta M+","description":"\u003cp\u003eTheta M+ transducer is used to measure and convert parameters of a single-phase or three-phase AC system with unbalanced or balanced load into a proportional load independent DC current or DC voltage output signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4-in-1 programmable transducers\u003cbr\u003e\u003c\/strong\u003eMeasurement parameters like voltage, current, power, frequency, and many more can be configured to any analogue or digital output. Voltage or current, Linear or Bent characteristic configurable for all analogue output. Digital output is configurable to pulse output, limit output, or timer output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFast Response Time\u003cbr\u003e\u003c\/strong\u003eAnalog Output response time is less than 300 msec.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring Input\u003cbr\u003e\u003c\/strong\u003eAC voltage\/current input signal, sine wave, or distorted waveform up to 31st harmonics. Measurement of instantaneous values of more than 50 quantities (Voltage, Current, Power (W, VAR, VA), Power Factor, Phase Angle, Frequency, System and Per Phase Demand, THD, System and Per Phase Energy (Wh, VArh, Vah).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest In-Class Accuracy\u003cbr\u003e\u003c\/strong\u003eTransducer Class 0.2 Accuracy as per IEC 60688. Active Energy Class 0.5s as per 62053-22.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUSB Communication\u003cbr\u003e\u003c\/strong\u003eThe transducer can be configured onsite using USB. USB is self-powered so device configuration is possible, both with and without auxiliary supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRS485 Communication Interface\u003cbr\u003e\u003c\/strong\u003eAn optional MODBUS RS-485 interface for monitoring and configuration purposes is also provided.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable Input \/ Output\u003cbr\u003e\u003c\/strong\u003eTransducer Input and Outputs can be programmed on-site using USB or RS-485 Interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance with International Safety standards\u003cbr\u003e\u003c\/strong\u003eCompliance to International Safety Standard IEC 61010- 1-2010\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Compatibility\u003cbr\u003e\u003c\/strong\u003eCompliance with international standard IEC 61326.\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561207603587,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta_M_new-product-300x300.jpg?v=1773234462"},{"product_id":"theta-pi-102","title":"Theta PI102 – Programmable Dual output DC Isolator","description":"\u003cp\u003e\u003cstrong\u003eTHETA PI 102:\u003c\/strong\u003e Programmable Dual output DC Isolator\u003c\/p\u003e\n\u003cp\u003eThe purpose of the THETA PI-102 is to electrically isolate input, outputs and power supply. The isolator fulills all requirements and regulation concerning electromagnetic compatibility EMC and safety (IEC61326-1 and IEC 61010-1:2010).\u003c\/p\u003e\n\u003cp\u003eThe device has one input and provides two independent outputs in an extremely small space.\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561248629123,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/Theta_PI102-332x332.jpg?v=1773234739"},{"product_id":"theta-pi-101","title":"Theta PI-101 Programmable Dual Output DC Isolator","description":"\u003cp\u003e\u003cstrong\u003eThe Theta PI-101 Programmable Dual output DC Isolator from Sifam Tinsley\u003c\/strong\u003e\u003cspan\u003e is used to electrically isolate input, output and power supply. The isolator fulfills all requirements and regulation concerning electromagnetic compatibility EMC and safety (IEC61326-1 and IEC 61010-1:2010). The device has one input and provides one independent output in an extremely small space.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561334808963,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta_PI-101-300x300.jpg?v=1773234860"},{"product_id":"theta-60i","title":"Theta 60I – Isolating Amplifier","description":"\u003cp\u003e\u003cspan\u003eThe purpose of the isolating amplifier Theta 60I is to electrically insolate input and output signals, respectively to amplify and \/ or change the signal level or type (current or voltage) of the input signals.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561470435715,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/theta60I-1-332x332.jpg?v=1773235000"},{"product_id":"p17-temperature-transducer","title":"P17 – Temperature Transducer 4\/20mA","description":"\u003cp\u003e\u003cspan\u003eThe P17 transducer is destined to convert the signal from temperature, resistance or voltage sensors into a 4…20 mA current signal.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561588695427,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P17-1-332x332.jpg?v=1773235237"},{"product_id":"p17g","title":"P17G – Separator (supplied from Current Loop)","description":"\u003cp\u003e\u003cstrong\u003eP17G:\u003c\/strong\u003e\u003cspan\u003e– separator supplied from a current loop.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561665700227,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/p17g.jpg?v=1787674576"},{"product_id":"p18-d-l","title":"P18D\/P18L – Temperature Humidity Sensor","description":"\u003cp\u003e\u003cstrong\u003eP18\u003c\/strong\u003e\u003cspan\u003e Transducer of temperature and standard signals. It is the device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a digital or analog standard signal. Additionally P18D transducer is equipped in LCD screen.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561670156675,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P18-1-332x332.jpg?v=1773235470"},{"product_id":"p19","title":"P19 – Temperature and Humidity Transducer","description":"\u003cp\u003e\u003cstrong\u003eP19\u003c\/strong\u003e\u003cspan\u003e Temperature and Humidity Transducer.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561680675203,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P19-1-332x332.jpg?v=1773235607"},{"product_id":"p20-temperature-standard-signal-transducer","title":"P20 – Programmable Temperature Signal Transducer","description":"\u003cp\u003eThe P20 programmable transducer is destined to convert the temperature, resistance, voltage from shunt and standard signals into a standard constant-current or constant-voltage signal.\u003c\/p\u003e\n\u003cdiv class=\"Opis\"\u003eThe transducer output signal is galvanically insulated from the input signal and the supply The device fulfils the requirements of III installation’s category for the products designed to industrial application –\u003ca href=\"http:\/\/www.youtube.com\/watch?v=DzDPh_VqECM\" rel=\"noopener\" target=\"_blank\"\u003e \u003cb\u003esee the video presenting, how important it is.\u003c\/b\u003e\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561726321027,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P20-1-332x332.jpg?v=1773235727"},{"product_id":"p20h-high-dc-signal-transducer","title":"P20H – Programmable DC Transducer","description":"\u003cdiv class=\"Opis\"\u003eTransducers of P20H types are applied for the continuous conversion of d.c. voltage and d.c. current into a standard d.c. current, d.c. voltage signal or RS-485 digital signal.\u003c\/div\u003e\n\u003cdiv class=\"RegionyCech\"\u003e \u003c\/div\u003e\n\u003cp\u003eThe device fulfils the requirements of III installation’s category for the products designed to industrial application – \u003ca href=\"http:\/\/www.youtube.com\/watch?v=DzDPh_VqECM\" rel=\"noopener\" target=\"_blank\"\u003e\u003cb\u003esee the video presenting, how important it is.\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561835405699,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P20H-1-332x332.jpg?v=1773235958"},{"product_id":"p20z-ac-signal-transducer","title":"P20Z – AC Current or AC Voltage Transducer","description":"\u003cdiv class=\"Opis\"\u003eMeasuring transducer P20Z type is destined to a continuous conversion of the rms current value or alternating voltage without the constant component into a standard d.c. current or d.c. voltage signal.\u003c\/div\u003e\n\u003cdiv class=\"RegionyCech\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"RegionyCech\"\u003eThe transducer output signal is galvanically insulated from the input signal and the supply. The device fulfils the requirements of III installation’s category for the products designed to industrial application –\u003ca href=\"http:\/\/www.youtube.com\/watch?v=DzDPh_VqECM\" rel=\"noopener\" target=\"_blank\"\u003e \u003cb\u003esee the video presenting, how important it is.\u003c\/b\u003e\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57561935643011,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P20Z-1-332x332.jpg?v=1773236095"},{"product_id":"p21z-ac-signal-transducer","title":"P21Z – Programmable AC Current or AC Voltage Transducer","description":"\u003cdiv class=\"Opis\"\u003eMeasuring transducer P21Z type is destined to a continuous conversion of a.c. current or a.c. voltage without the constant component or frequency into a standard d.c. current or d.c. voltage signal or digital signal.\u003c\/div\u003e\n\u003cdiv class=\"RegionyCech\"\u003eThe transducer output signal is galvanically insulated from the input signal and the supply. The device fulfils the requirements of III installation’s category for the products designed to industrial application –\u003ca href=\"http:\/\/www.youtube.com\/watch?v=DzDPh_VqECM\" rel=\"noopener\" target=\"_blank\"\u003e \u003cb\u003esee the video presenting, how important it is.\u003c\/b\u003e\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562040238467,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P21Z-1-332x332.jpg?v=1773236261"},{"product_id":"p30h","title":"P30H – LCD Programmable DC Circuit Parameters with Ethernet","description":"\u003cp\u003e\u003cstrong\u003eP30H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a transducer which was designed to photovoltaic , battery, telecommunication and railway installations. P30H measures and records current, voltage, power, energy and other d.c. circuit parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"alignnone wp-image-6314 size-large\" src=\"https:\/\/sifamtinsley.co.uk\/wp\/wp-content\/uploads\/2020\/03\/p30h-example-1-1024x377.jpg\" alt=\"\" width=\"640\" height=\"236\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe output signal is galvanically isolated from the input signal and the power supply. P30H has programmable measurement and additional functions. Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers (see how it works: login – user, password – pass).\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562178552195,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P30H-1-332x332.jpg?v=1773236444"},{"product_id":"p30-o","title":"P30O – LCD Pulse\/Frequency\/Turns\/Operation Time Transducer with Ethernet","description":"\u003cp\u003e\u003cstrong\u003eP30 O\u003c\/strong\u003e\u003cspan\u003e Transducer of pulses, frequency, turns and operation time.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562246644099,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P30O-1-332x332.jpg?v=1773236598"},{"product_id":"p30o-frequency-transducer","title":"P30O Frequency Transducer","description":"\u003cp\u003e\u003cspan\u003eProgrammable transducer P30O type is destined to convert of number of pulses, number of working hours, frequency, period and rotational speed into a digital or standard current or voltage signal.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562324828547,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P120-1-332x332.jpg?v=1773236705"},{"product_id":"p30p","title":"P30P – LCD Transducer 1 Phase Power Network with Ethernet","description":"\u003cp\u003e\u003cspan\u003eTransducer of 1-phase power network parameters.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562329776515,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P30P-1-332x332.jpg?v=1773236828"},{"product_id":"p30u-universal-input-transducer","title":"P30U – DC Temperature Transducer","description":"\u003cp\u003e\u003cspan\u003e\u003cb\u003eUniversal transducer of temperature and standard signals with Ethernet\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eP30U transducer is designed to convert temperature, resistance, standard voltage and current signals into a standard DC voltage or DC current signal. The output signal is galvanically isolated from the input signal and the power supply. P30U has programmable measurement and additional functions.  Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers via Ethernet interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.youtube.com\/watch?v=DzDPh_VqECM\" rel=\"noopener\" style=\"font-size: 0.875rem;\" target=\"_blank\"\u003e\u003cb\u003eSee the video presenting, how important it is.\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562335183235,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P30U-1-332x332.jpg?v=1773236966"},{"product_id":"p43","title":"P43 – Programmable 3 Phase Power Transducer","description":"\u003cp\u003e\u003cspan\u003eIt Programmable Transducer of 3-Phase Power Network Parameters.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57562341540227,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/P43-1-332x332.jpg?v=1773237165"},{"product_id":"theta-hsc-series-open-loop-current-transformer-1","title":"Theta HSC Series Open Loop Current Transformer","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb\u003eTheta HSC Series Open Loop Current Transformer\u003c\/b\u003e\u003cspan\u003e is a transducer designed to convert input current signal into output voltage. The transducer converts a sinusoidal AC Current (Up to 25kHz frequency of the input signal) ,DC Current or Pulsating DC current into a corresponding output voltage proportional to the measured value. The transducer output is galvanically isolated from the input signal and auxiliary supply.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley","offers":[{"title":"Default Title","offer_id":57625656557955,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/CW-series-CT-300x300_1.gif?v=1773838120"},{"product_id":"theta-tpt","title":"Theta TPT","description":"\u003cp\u003e\u003cstrong\u003eTHETA TPT\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eProgrammable Tap position transducer\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003ewith dual output, display and modbus (DIN Mounted).\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eOur Tap position transducer Theta TPT converts resistance to proportional analogue output signal. The purpose of the Tap position transducer is to convert tap position of transformers to equivalent analogue output. Outputs can be given as input to either RTU or indicator or recording instrument. The device has one input channel and two independent outputs. Programmable input tap resistance(2\/3\/4 wire measurement) upto 25kOHM is converted to proportional 1 or 2 analog o\/p signal either Idc or Vdc, Universal AC\/DC aux With LED Display.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sifam Tinsley UK","offers":[{"title":"Default Title","offer_id":62509674037635,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/files\/Theta_TPT-600x600.jpg?v=1788271465"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/2745\/4595\/collections\/transducer_isolator-clear.png?v=1784042519","url":"https:\/\/sifamtinsley.co.uk\/collections\/transducers-isolators.oembed","provider":"Sifam Tinsley UK","version":"1.0","type":"link"}